DB-PX5 - PowerVisa 440® / PowerGuide® 4400 / PowerXplorer® PX5 Op. Skills
© 2006-2010 by PowerCET Corporation. All rights reserved. (100616)
52
©2006-2008 PowerCET Corporation. All rights reserved.
103
•Press a category, then press
repeatedly the parameter that
you want to change to display
the available selection values
•Power Values: Interval
(seconds): OFF, 1, 60, 120, 300,
600, 900, 3600
•Waveform Snapshot: OFF, ON
•Demand and Energy: Demand
Sub-Interval (minutes): OFF, 3, 5,
10
•Sub-Intervals per Interval
(minutes): OFF, 1, 2, 3, 4, 5, 6
•Harmonics: (minutes): OFF, 1, 2,
5, 10, 15, 60
•Flicker: Pst (Short Term) Interval
(minutes): OFF, 1, 2, 5, 10, 15, 30
Plt (Long Term) Interval (hours):
OFF, 1, 2, 3, 4, 8
•Press: Finish to return to
Advanced Options
Wizard Setup: Journal Interval
©2006-2008 PowerCET Corporation. All rights reserved.
104
•Power Values: Interval (seconds):
OFF, 1, 60, 120, 300, 600, 900, 3600
[Press a category, then press
repeatedly the parameter that
you want to change to display
the available selection values.]
•Waveform Snapshot: OFF, ON
•Demand and Energy: Demand Sub-
Interval (minutes): OFF, 3, 5, 10
•Sub-Intervals per Interval
(minutes): OFF, 1, 2, 3, 4, 5, 6
[Press a category, then press
repeatedly the parameter that
you want to change to display
the available selection values.]
Wizard Setup: Journal Interval—Power Value…
Comentarios a estos manuales